  Datasheet File OCR Text:
 MicroPower Direct
Go Direct - MicroPower Direct - For Product, Performance and Price
400W AC-DC ACTIVE PFC MEDICAL POWER SUPPLY MPA400M SINGLE OUTPUT SERIES
FEATURES:
* * * * * * *
U - Chassis Type: 8 x 5 x 1.6" Enclosed with built-in fan Type: 9 x 5 x 1.6"
Medical Safety Approvals Optional N+1 Forced Active Current Sharing Power Factor Corrected to EN61000-3-2 class D Providing Peak Power 700W within 500uS duty duration U-Chassis & Enclosed with built-in fan Mechanical Options 1U height size and High power density: 6.25 watts/cu inches Current Monitoring and Remote Voltage adjustment (Margin)
PRODUCT SPECIFICATIONS:
Input Voltage: 90-264 Vac full range, 47~63 Hz. Input Current: 6.35A at 90VAC full load. Inrush Current: 35A Max @ 230 Vac with full load and cold start. PFC: Active power factor correction meet EN61000-3-2 class D. Fan Drive: 12VDC/400mA is available to drive an external fan. Transient Response: Returns to within 1% in less than 2.5 mS for a 50% load change and the peak transient does not excess 5%. Overshoot: Turn-on/off not exceed 5% over nominal voltage. Efficiency: 82% minimum (Measuring at 230V and full load). Turn On Delay: 1 second maximum at 120 VAC. Hold Up Time: 20 mS min. at 80% of full load. Adjustability: Output user adjustable 5% minimum. Remote Sense: Designated "RS+" and "RS-" on the CN3. (Not available for current sharing models) Remote On-Off: Designated as "RSW" on the CN3, requires a low signal to inhibit output. Power Supply On: Green LED designated as "LED 1" on the PCB. LED display: Bi-color "LED1" emit green light on operating. Any protection occurred or RSW applied low signal will emit orange. Power Good: Designated as "PG" on the CN3 will go high 100500 mS after regulation and goes low 1mS before loss of regulation. Current Sharing: Designated as "CSH" on the CN3, optional single wired for forced current sharing function and parallel up to 4 units within 10% accuracy at full load. Current Monitor: Designated as "CMN" on the CN3 for current sense for a 0.5V to 3 VDC to represent 0% to 100% output current. Margin: Designated as "MGN" on the CN3 providing 50% of output voltage remote adjustment by applying 0.4 ~ 5V signal on "MGN". AC Fail (optional): Designated as "ACF" on the CN3 to monitor the input voltage, when input goes under 80 +/- 5VAC the signal will go low (0V) and then go high (+5V) once reappears over 86 Vac. (Input voltage protection must be disabled when AC Fail is enable.) Input Circuit (primary): Two protected fuse inserted, shall be blown only by an internal power fault.
CB
Input Voltage Protection: Power shut down under 80 5 Vac, and recovered over 86 Vac.(Disabled unless AC Fail is requested) Over-Power Protection: C.C. mode 110-140% and auto-recovery. Over-Voltage Protection: Latching down will occur when output voltage exceed 130% and recycle AC input to reset. Short Circuit Protection: Trip without damage and auto-recovery. Over Temperature Protection: Protected in the event of excessive operating ambient 85C, with automatic recovery. Switching Frequency: 30 kHz fixed frequency. Operating Temperature: O to 70C ambient, de-rating at 2.5% per degree from 50C to 70C. Storage Temperature: -20 to 85C. Operating Humidity: 5% to 90% RH, Non-condensing. Storage Humidity: 5% to 95% RH, Non-condensing. Vibration: Frequency 5 to 50 Hz, acceleration +/-7.35 M/(SxS) on X,Y and Z Axis. Emissions: FCC Part 15, CISPR 22 class B, Conducted. Safety Regulation: Approved to UL60950-1/ 60601-1, CSA C22.2 No. 60950-1-03/ 601.1-M90, TUV EN60950-1/ 60601-1, CE Mark (LVD) EN61204-3/ 60601-1-2/ 61000-3-2,3 & IEC61000-4 Series Regulations and CB. Leakage Current: 300uA HI-POT Test: 1500 Vac between input line and chassis (2mA DC cut off current); 4000 Vac between primary and secondary windings; Primary to core 1500 VAC. All for 3 sec. Grounding Test: Apply 40 A from ground pin to the earthed connection point. Maximum allowable resistance is 0.1ohm. Warranty: 2 years. MTBF: 100000 Hrs (according to MIL-HBK-217F) at 30? . Cooling: External forced air requires achieving full ratings. Burn in: 45 +/- 5C for 1 hour @ 230 Vac with full load. Enclosure: U-Chassis type - 8(L) x 5(W) x 1.6(H) inches. Enclosed type - 9(L) x 5(W) x 1.6(H) inches. Weight: U-Chassis Type - 1.3KG; Enclosed Type - 1.6KG;
MicroPower Direct
www.micropowerdirect.com
292 Page Street, Ste D Stoughton, MA 02072 * TEL: (781) 344-8226 * FAX: (781) 344-8481 * EMAIL: sales@micropowerdirect.com
OUTPUT VOLTAGE / CURRENT RATING CHART: Measured at output power connector.
Max. Output current Model MPA400MXY-03Z MPA400Mxy-05z MPA400Mxy-12z MPA400Mxy-18z MPA400Mx y-24z MPA400Mxy-36z MPA400Mxy-48z Output Range
2 - 3.3V 5 - 6V 12 - 15V 16 - 21V 22 - 30V 31 - 41V 42 - 58V
Preset Voltage
3.3V 5V 12V 18V 24V 36V 48V
Convection
45A 45A 20.84A 15.64A 11.37A 8.07A 5.96A
22.95CFM
60A 60A 33.34A 25A 18.19A 12.9A 9.53A
Total Regulation
+/- 1% +/- 1% +/- 1% +/- 1% +/- 1% +/- 1% +/- 1%
Ripple & Noise
+/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1%
* MPA400Mxy-00z x = E (Enclosed Type) or U (U-Chassis Type); y = Blank (Standard) or I (Forced current sharing option, Oring Diode); z = Blank (terminal strips), M (Molex Connectors) or I (IEC Input Connector, Enclosed unit only). * Max power 400W continuous output with min. 22.95CFM forced air cooling or built-in fan. Convection cooled rating as above chart. * All output ranges are covered in agency certifications and preset output voltage for each model as above listings. * Providing peak power to 700W within 500uS for all models, longer duty duration need contact manufacture. * 1% minimum load is required to maintain the ripple and regulation. * Output is fully isolated. * Cover is optional for U-Chassis enclosure.
OUTLINE DRAWING:
Overall Size for U-Chassis Type: 8(L) x 5(W) x 1.6(H)inches; Weight: Maximum weight is 1.3kg
B: M O U NTIN G H O L E 8 P LACE 6 -32 U N C(Zn -p la t e d ) SCALE 4 :1
FAN
I/O Connector pin assignment:
Input Connector(CN1): U-Chassis Type - mating Molex Part No. 09-910700 equivalent(7 pin, 5 used), or Howder Terminal block Part No. HD-121-3P. Enclosed type - IEC320 or equivalent Snap-in mounting type or DINKLE Terminal block Part No. DT-35-A02W-03 (3 pin) Output Connector (CN2): Mating Molex 16 pins (09-91-1600), or Howder (HD-121-6P) M3.5, 8 pins terminal block, 9.5MM Center. Output Pin Assignment: (See Table Below)
CN2
C B
C B
B C
B C
FAN
CN3
B
VO-
CN1
VO-
B
C B
C:M O U N TIN G H O LE 8 P LACE M 4 X0 .7 U NC SCAL E 4 :1
VO+
VO+
L N
C
B C B C
Logic signal connectors (CN3): Mating JST XHP-8 or equivalent (CHYAO SHIUNN JS-2001-08) Mating Pins: JST SXH002T-P0.6 for AWG 30 to 26.
Fan driver connector (FAN): 12 VDC / 400 mA is available to drive an external fan. Mating connector is a JST XHP-2 or Molex P/N 48-151-0210 ( 2 pins 0.98 pitch). Mating Pins: JST SXH-001T-P0.62T or Molex 48150 .
Overall Size for Enclosed Type: 9(L) x 5(W) x 1.6(H)inches; Weight: Maximum weight is 1.6kg
C B
C B
Mounting Inserts: 6-32, M4 4 Places individually with maximum penetration 0.15" on bottom side and 0.25" on both side.
B C
B C
FAN VO-
VO-
Molex
C B C B
Howder (Pins 1-3) (Pins 4-6)
VO+
VO+
LN
B C B C
VO+ VO-
(Pins 1-8) (Pins 9-16)
MO UNTING HOLE: B: 6 -32 UNC (Zn -p la t e d ) 8 PLACE C: M4 X0 .7 UNC 8 PLACE
MicroPower Direct
www.micropowerdirect.com
292 Page Street, Ste D Stoughton, MA 02072 * TEL: (781) 344-8226 * FAX: (781) 344-8481 * EMAIL: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of MPA400MXY-03Z

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X